ASSEMBLY
Read this manual. Do not attempt to operate
equipment until you have read this Manual for
Safety, Operation, and Maintenance Instructions.
NOTE: This manual is a general manual. Information
in this manual may or may not pertain to your model.
Please read carefully.
NOTE: Left and right describes the location of a part
with the operator facing the outlet panel.
REMOVE GENERATOR FROM CARTON
• Open carton from top.
• Cut carton along dotted lines.
• Remove all carton inserts.
• Remove generator through opening in carton.
• (if equipped) Remove shipping block from under
the gen head by unscrewing the bolt and remove the
wood block. It is very important that this is removed
before starting your generator. See Figure 1.
IMPORTANT: Before any attempt to start your generator
be sure to check engine oil (See Engine Operator's
manual)
GROUNDING THE GENERATOR
A grounding lug is supplied with the generator for use
when required by local electrical ordinances. Refer to
article 250 of the National Electrical Code to clarify any
needed grounding information. Your local electric
company or a certified electrician should be able to help
you with this information.
Figure 1
TYPICAL INSTALLATION OF BATTERY
(Electric Start Units Only)
● Recommended Battery for Electric Start: 12V - 45
A H. or 210 CCA (Cold Cranking Amps)
● Purchase battery and battery hardware separately,
not included with unit.
1. Place battery in rack with terminals facing towards
generator head.
2. Place battery bracket (A) over battery as shown in
Figure 3 (opposite battery terminals).
3. Place "L" bolt (B) through top and bottom brackets
and secure with wing nut (C).
To Prevent sparks connect the red (positive)
cable to the positive (+) terminal before connect-
ing the black negative cable.
4. Locate the solenoid on the left side of the unit. See
Figure 4 and 5.
For GBE4010 and GBFE6010
5. Remove the nut from the solenoid post with the
panel assembly wire harness. Place one end of the
positive (red) battery cable onto this post with the
panel assembly wire. Reassemble nut and tighten
securely. See Figures 4.
Figure 3
Figure 4
Grounding Lug
Figure 2
NOTE: Your engine is already grounded to the frame by
a grounding strap.
Panel Assembly
Wire Harness
Solenoid