Vista de pagina 0
Record All Information
for future reference:
Brand:
Purchase Date:
Model #:
Serial #:
Questions? 1-800-888-2468
Register your product online
www.devap.com
CONSUMER SAFETY INFORMATION . .2
SAFETY GUIDELINES/DEFINITIONS . .2
SAFETY INSTRUCTIONS . . . . . . . . . .2-8
ASSEMBLY . . . . . . . . . . . . . . . . . . . .9-11
OPERATION . . . . . . . . . . . . . . . . . .12-14
MAINTENANCE . . . . . . . . . . . . . . .15-16
STORAGE . . . . . . . . . . . . . . . . . . . .17-18
WATTAGE CALCULATIONS . . . . . . .17-19
TROUBLESHOOTING GUIDE . . . . . . .20
WARRANTY . . . . . . . . . . . . . . . . . . . . .21
QUICK FACTS . . . . . . . . . . . . . . . . . . .22
ESPAÑOL . . . . . . . . . . . . . . . . . . . . . . . . . . .23-40
FRANÇAIS . . . . . . . . . . . . . . . . . . . . . .45-68
READ AND SAVE THESE INSTRUCTIONS
Generator
Operator’s Manual
Part No. D25572 Rev. 0
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - Generator

Record All Informationfor future reference:Brand:Purchase Date:Model #:Serial #:Questions? 1-800-888-2468Register your product onlinewww.devap.comCONS

Pagina 2 - CONSUMER SAFETY INFORMATION

10- ENGD25572FOR GBE4010 AND GBFE60105. Remove the nut from the solenoidpost with the panel assembly wireharness. Place one end of the posi-tive (red)

Pagina 3 - IMPORTANT SAFETY INSTRUCTIONS

11- ENGD25572EXTENSION CORDSWhen using an appliance or tool at a considerable distance from the generator, a3-wire extension cord that has a 3-blade g

Pagina 4 - HOW TO PREVENT IT

12- ENGD25572OPERATIONKNOW YOUR GENERATORRead this General Manual and Safety Rules before operation of your Generator.Compare the illustration in your

Pagina 5

13- ENGD25572Engine speed has been factory set to provide safe operation.Tampering with the engine speed adjustment could result in over-heating of at

Pagina 6

14- ENGD25572STOPPING ENGINE1. Disconnect all electrical loads.2. (if equipped) Turn ON/OFF switch to "OFF" position.3. Close fuel shut-o

Pagina 7

15- ENGD25572CONNECTING PROCEDURE FOR RAISING OR SUSPENDINGGENERATORS EQUIPPED WITH LIFT RINGSFailure to properly connect lifting cables, chains, or s

Pagina 8

16- ENGD25572If you are going to store your generator for more than 30 days, use thefollowing information as a guide to prepare the generator for stor

Pagina 9 - ASSEMBLY

17- ENGD25572BATTERY (ELECTRIC START UNITS ONLY)• Store battery as described by the battery manufacturer.NOTE: After storing battery for a long per

Pagina 10 - GBVE8000

18- ENGD255723. The running wattage of examples 1 & 2 totals 1150 watts. The startingwattage of the small refrigerator is 2000 watts which is 1500

Pagina 11 - DOUBLE THROW TRANSFER SWITCH

19- ENGD25572APPLIANCE OR LOAD DEVICE* REFRIGERATOR/ FREEZER 800 SMALL REFRIGERATOR AIR COND.(ROOM) SUMP PUMP 1/2 HP 600 TELEVISION CAUTION !! HOT PLA

Pagina 12 - OPERATION

2- ENGD25572Read Operators Manual. Do not operate equipment until you have readoperators Manual for Safety, Assembly, Operation, and MaintenanceInstru

Pagina 13 - (Recoil start/Pull start)

20- ENGD25572TROUBLESHOOTING GUIDEPROBLEMCAUSECORRECTIONEngine will notstart1. Low on fuel or oil.2. Ignition switch in "Off"position.3. Fau

Pagina 14 - CONNECTING ELECTRICAL LOADS

21- ENGD25572LIMITED WARRANTYDeVilbiss Air Power Company warrants to the original purchaser who uses the product in aconsumer application (personal, r

Pagina 15 - MAINTENANCE

22- ENGD25572CALL 1-800-888-2468 EXT 2TO FIND A LOCAL AUTHORIZED SERVICE CENTER NEAR YOU FOR REPAIRSAND SERVICE PART PURCHACES.QUICK FACTSALWAYS REFER

Pagina 16 - RECEPTACLE)

3- ENGD25572indicates an imminently hazardous situation which, if not avoided, will resultin death or serious injury.indicates a potentially hazardous

Pagina 17 - WATTAGE CALCULATIONS

4- ENGD25572Operation of unitwhen damaged,or with guards orpanels removed.Removal of guarding couldexpose electrically chargedcomponents and result in

Pagina 18 - Application Guide

5- ENGD25572RISK OF FIREHAZARDWHAT CAN HAPPENHOW TO PREVENT ITImproper storageof fuelImproperly stored fuel couldlead to accidental ignition. Fuelimpr

Pagina 19 - CAUTION !!

6- ENGD25572RISK OF UNSAFE OPERATIONHAZARDWHAT CAN HAPPENHOW TO PREVENT ITOperation ofgenerator incareless mannerAll sources of energy include thepote

Pagina 20 - TROUBLESHOOTING GUIDE

7- ENGD25572RISK OF UNSAFE OPERATION(Continued)HAZARDWHAT CAN HAPPENHOW TO PREVENT ITImproper raising or suspendingcan cause damage to thegenerator.Al

Pagina 21 - LIMITED WARRANTY

8- ENGD25572HAZARDWHAT CAN HAPPENHOW TO PREVENT ITHAZARDWHAT CAN HAPPENHOW TO PREVENT ITRISK OF MOVING PARTSNever operate generator withguarding or co

Pagina 22 - QUICK FACTS

9- ENGD25572NOTE: This manual is a general manual. Information in this manual may ormay not pertain to your model. Please read carefully.NOTE: Left

Comentarios a estos manuales

Sin comentarios